Connect, choose your ECU profile, and build a screen cycle.

CAN Bus Gauges displays supported ECU broadcast data on a configurable touchscreen. Available layouts and controls depend on the connected display, firmware, ECU profile, and enabled ECU broadcasts.

This manual covers the current compact round, wide, and square display families. The configurator checks the connected device before offering a feature; a disabled control can indicate older firmware or a feature your model does not support.

  1. Identify your display and obtain its exact installation sheet before wiring.
  2. Complete installation with vehicle and bus power off, then verify the ECU broadcast setup.
  3. Connect the Windows configurator over USB or Bluetooth and read the gauge.
  4. Select the matching ECU profile, units, screens, and warning limits. Save to gauge and confirm success.
  5. Check live readings against your ECU software while stationary. Turn Demo Mode off before using the display for monitoring.

Configure and test while parked. Gauge warnings supplement the ECU and normal instruments; they do not replace engine protection or a safe installation.

BACK TO TOP ↑

Choose a display

Three display sizes share one configuration workflow.

Compact 1.75-inch: round 466 × 466 AMOLED touchscreen. Supports single-parameter screens, dual-parameter presentation, and two four-parameter dashboards. Compact dual layouts stack the two primary gauges vertically.

Wide 4.3-inch: 800 × 480 touchscreen. Adds a six-parameter dashboard, a Wide Dashboard with one primary and six secondary values, and dual-primary layouts with six compact companion values.

Square 4-inch: 480 × 480 touchscreen. Uses a two-column, three-row six-parameter layout. Its expanded dual display places two primary gauges above six companion values.

Display diagonal and resolution do not establish enclosure size, mounting diameter, cutout, ingress protection, supply voltage, or sunlight rating. Use the exact product installation drawing for those specifications.

Round 1.75 is the compact retail family presented on this site. Always match the firmware package to the device identity reported by the configurator.

BACK TO TOP ↑

Installation and CAN wiring

Use the exact harness and installation sheet for your display.

Each product includes its display, relevant housing, and a 6 ft harness. Round 1.75 uses a cylindrical gauge-pod body designed for a typical 52 mm opening; confirm actual cutout, mounting depth, and clearance. Wide 4.3 and Square 4 include an upright housing/mount. Rotary controllers include their housing, with exact mounting dimensions to be confirmed. Shipping is charged separately.

Power input and connector pinouts vary by hardware. Do not infer a power rating or CAN pinout from another display with the same screen size. The customer harness specification must identify power, ground, CAN High, and CAN Low before connection.

Connect to the ECU's supported CAN network and match the selected bitrate. CAN High and CAN Low are a differential pair; swapped wires, unsuitable termination, grounding faults, and mismatched bitrates can prevent valid data.

Some development hardware uses external transceivers and special reset-sensitive wiring. Those bench procedures are not an installation guide for a finished vehicle product.

  1. With power off, compare the display label and harness with its installation sheet.
  2. Confirm the power source, fuse requirement, ground, connector orientation, and CAN High/Low pins.
  3. Check network termination according to the ECU and display installation documentation. Avoid adding an extra terminator without checking the existing network.
  4. Secure wiring away from heat, abrasion, moving parts, and interference sources.
  5. Power up and compare several stable readings with the ECU software before operating the vehicle.

An RS485 connector is not a CAN connector, even when its markings look similar.

No universal customer harness pinout, input-voltage specification, or mounting drawing was established from the reviewed firmware. Confirm those details for the supplied assembly before installation.

BACK TO TOP ↑

ECU compatibility

Select the exact broadcast profile, not just an ECU brand.

MegaSquirt MS3: 500 kbit/s CAN with standard 11-bit identifiers. The current catalog contains 301 logical choices backed by 321 wire records. The selected signal must actually be broadcast by the ECU.

DTA T-Series: 1 Mbit/s CAN with extended identifiers and a 74-signal catalog. Protocol selection and profile restoration have been tested on physical gauges; live DTA ECU/CAN validation remains pending.

Haltech: Broadcast Protocol 2.0 receive implementation at 1 Mbit/s with standard identifiers, covering 321 selectable channels across 63 frames. Nexus firmware 1.25+ and Elite 3.11+ provide the documented full catalog; older versions may provide a subset. Platinum is outside this profile. Live Haltech ECU/CAN validation remains pending.

  1. Check your ECU family, firmware version, and broadcast protocol.
  2. Select the matching ECU Type in the configurator.
  3. Apply the change. The gauge saves the selection and restarts; allow the configurator to reconnect.
  4. Confirm the active protocol and bitrate in Diagnostics, then read the active profile before editing.

Protocol catalogs are alternatives, not a promise of simultaneous multi-ECU decoding or universal CAN compatibility.

Display support does not imply output-control support. Virtual Controls has separate ECU and firmware requirements.

The profile change preserves separate supported screen/control settings for each ECU profile.

BACK TO TOP ↑

Set up MegaSquirt broadcasting

Enable the ECU broadcasts needed by your chosen parameters.

The standard dash broadcast provides familiar values including RPM, coolant temperature, throttle position, manifold pressure, and battery voltage. Additional catalog parameters require their matching advanced realtime broadcast groups.

Check-engine information uses advanced broadcasting at the default base of 1520: groups 54 and 60, plus optional group 51 for the numeric ECU error code. The minimal dash stream alone does not provide those fields.

  1. Use the ECU's current TunerStudio project and official CAN broadcast instructions.
  2. Enable the dash or advanced realtime broadcast groups needed by the selected signals.
  3. Use 500 kbit/s standard CAN for the MS3 display profile.
  4. Verify the gauge's chosen values against TunerStudio. If one value is missing while others work, check that value's broadcast group.

The catalog is broader than the minimal dash broadcast. A listed parameter is not evidence that your ECU is currently sending it.

Virtual Controls setup is a separate receiving configuration and is not required to use the display.

BACK TO TOP ↑

Connect the Windows configurator

Use a USB data cable or Windows Bluetooth.

The application offers Windows Bluetooth, USB cable, and a simulator. Simulator mode is useful for exploring the interface without hardware.

Bluetooth scanning lists devices that advertise during the scan. USB discovery checks supported native USB devices and verifies device identity rather than trusting a COM port number alone.

  1. Open Connection and select Windows Bluetooth or USB cable.
  2. Choose Scan, select the intended gauge, then Connect.
  3. After connection, choose Read from gauge to replace current edits, or Keep current edits to retain your local draft.
  4. Check Diagnostics for the device identity, display resolution, firmware, protocol, and supported features.
  5. Use Disconnect before switching devices or powering down.

Use a data-capable USB cable. A charge-only cable can power the display without making it configurable.

Windows must allow Bluetooth or serial-device access. A firmware update may be required when the app reports an incompatible configuration version.

A controller uses its own connection panel; verify the destination before a firmware or splash upload.

BACK TO TOP ↑

Read, save, and restore settings

Keep local drafts and saved device settings distinct.

Read from gauge retrieves the current device configuration. Save to gauge validates and writes changed compatible sections, then checks the saved result. Revert changes returns the draft to the last confirmed baseline; Restore defaults prepares default settings for review.

Load locally and Save locally work with a configuration file on the computer. Loading a file does not immediately change the gauge. Local package files are useful for backups and preparing a layout before connecting.

A coordinated save covers several sections in sequence; it is not one indivisible transaction. If interrupted, read the gauge and check the actual result before retrying.

  1. Read the gauge and save a local backup before substantial changes.
  2. Edit the required sections and review the preview and validation messages.
  3. Select Save to gauge and wait for confirmed completion.
  4. Reconnect or reread if the outcome is uncertain. Preserve your desired draft or local backup before replacing it.

Changing transport or connecting another gauge invalidates the previous device baseline. A fresh read is required before saving.

Startup images are managed separately and are not included in ordinary configuration JSON files.

Some on-display text-size settings for grid and Wide layouts are stored on the gauge and are not included in desktop configuration packages.

BACK TO TOP ↑

Build your screen cycle

Choose what each screen shows and the order you see it.

Screens & Dashboards contains six independent single-parameter screen identities, two four-parameter dashboards, and a dual-parameter screen. Expanded displays also support a six-parameter dashboard and Wide Dashboard.

A single screen can show a numeric value or a supported sweep style, with its own selected parameter, scale, warnings, and position in the screen cycle. Dashboard cells can be enabled independently.

The dual screen gives each primary gauge an independent parameter and scale. Expanded displays add six companion values. The Wide Dashboard uses one primary gauge with six secondary values.

  1. Open Screens & Dashboards and select a screen identity.
  2. Enable the screen, select its parameters, and choose the supported presentation.
  3. Set the scale where available. Use reviewed ranges as a starting point and verify them for your application.
  4. Arrange the enabled screens in the desired cycle order.
  5. Save to gauge, then test previous/next navigation.

Only enabled compatible screens participate in navigation. With one enabled screen, previous/next returns to the same screen.

Unsupported layouts remain available as local drafts where appropriate; the app prevents silently discarding data when saving to a smaller or older device.

BACK TO TOP ↑

Gauge styles and dashboard presentations

Match the display to the information you want to read.

Current style families include numeric, Motorsport needle, Neon halo, Digital block ring, and analog-inspired presentations. Full-size single screens also use names such as Telemetry index, Minimal needle, Panoramic sweep, and Vector hybrid. Some legacy styles remain available only in specific layouts or older saved configurations.

Additional single-screen styles include Horizon Ribbon, Quarter Fan, Panorama Needle, Rising Blocks, Shift Lights, Rising Tide, Retro Ramp, and Balance Beam. A four-parameter Quarter Fan presentation is also implemented on expanded displays.

Shift Lights uses colored capsule indicators over a large number. Rising Tide uses a level display. Retro Ramp combines a stepped bar with a seven-segment readout. Balance Beam shows movement from an origin that adapts to the configured scale.

  1. Select a single screen or supported dashboard.
  2. Choose a style from the connected device's available list.
  3. Preview it at the target's aspect ratio, then verify label length, units, scale, warning colors, and readability on the actual display.

Style availability depends on layout and firmware. The newest single-screen styles are not automatically available for Wide or Dual layouts.

Refresh performance varies with display and layout; no universal frame-rate guarantee is made.

BACK TO TOP ↑

Touch navigation and quick adjustments

Tap the sides to change screens; use deliberate holds and swipes for other actions.

Tap the outer left edge for the previous screen or the outer right edge for the next. Each side band occupies roughly 20% of the width. The middle does not change screens on a simple tap.

A short stationary tap acts on release. Dragging, leaving the side band, or holding too long cancels navigation. Horizontal swipes do not change dashboards.

Swipe downward to open display controls for brightness and, on supported full-size layouts, text size. Swipe upward from the bottom edge to open Virtual Controls when supported.

  1. Use a quick stationary edge tap to move through enabled screens.
  2. Tap the central peak/header target to switch Live and Peak.
  3. Hold the peak target for three seconds to clear the current screen's peaks.
  4. On supported parameter tiles, hold for three seconds to open the parameter picker.

Side taps take priority at header corners. Use the central header for peak commands.

Warnings and open overlays can temporarily take ownership of touch input.

Changing parameters and interacting with Virtual Controls should be done while stationary.

BACK TO TOP ↑

Replace a parameter on the display

Use a long press and a configurable shortlist.

Supported firmware can replace a displayed parameter through an on-device picker. A continuous three-second hold on an eligible tile opens the selection interface. The picker uses the active ECU catalog.

The configurator's Parameter Shortlist can expose the full eligible catalog or an ordered shortlist of up to 32 parameters. Shortlists are profile-specific.

  1. Prepare the shortlist in the configurator if you want a smaller on-display selection.
  2. Hold the intended parameter tile for three seconds without dragging.
  3. Choose a replacement from the available list and confirm the result.
  4. Read the gauge in the configurator before making later desktop changes so the latest on-device selection is included.

Touch loss, a screen/configuration change, or a warning interruption cancels the pending hold.

A replacement cannot make an ECU broadcast a signal that is not enabled at the source.

BACK TO TOP ↑

Units and sensor labels

Change presentation without changing ECU calibration.

Display units include °F/°C, kPa/psi/bar, MPH/km/h, and AFR/Lambda. AFR-to-Lambda conversion uses the configured stoichiometric AFR, from 5.00 to 25.50. Choose the value appropriate to the fuel and ECU data.

Compound manifold pressure in psi mode displays vacuum in inHg VAC, atmosphere as zero, and positive boost in psi BOOST. The display uses a fresh plausible barometric reading when available, retains its last valid reference for the session, and otherwise uses standard atmosphere. kPa and bar remain absolute pressure.

MS3 Generic Sensors 1–16 can have custom display names and unit labels. A custom unit label is presentation-only and does not rescale the number. Haltech's typed generic sensors use separate profile-specific interpretation options.

  1. Open Gauge Settings and choose the required unit preferences.
  2. Set and verify stoichiometric AFR when using AFR/Lambda conversion.
  3. Review scale and warning inputs in the selected units.
  4. Use Generic Sensors for names and labels, then save and compare the displayed value with the ECU.

Switching units reprojects settings instead of repeatedly converting the saved canonical values.

For compound pressure, low/vacuum and high/boost inputs have different directions. Resolve any validation message before saving.

Changing a unit label does not calibrate a sender or change the ECU signal's decoding.

BACK TO TOP ↑

Colors, themes, brightness, and text size

Tune the presentation for your installation.

Appearance supports separate text and sweep colors, plus secondary-tile colors and supported Virtual Controls colors. The editor provides RGB controls and a curated swatch gallery. Style names and shared color roles may differ between Single and Wide layouts.

Brightness ranges from 0 to 100%. On compatible firmware, moving the connected configurator slider applies brightness immediately from the confirmed settings baseline.

Expanded displays support 75%, 100%, 125%, and 150% text sizes. Single and Dual sizes can be edited per screen through compatible desktop firmware. The on-display controls also support grid and Wide text sizes. Compact displays retain their compact sizing.

The Themes workspace provides a reusable theme library. Display defaults, individual screens, components, and Virtual Controls can use linked themes or local overrides. Editing a built-in creates a separate theme. Configuration exports embed referenced themes so the file does not depend on another computer's library.

  1. Choose a style, then adjust the relevant text, sweep, tile, and control colors.
  2. Preview high and low values, warning states, and long labels.
  3. Use the display-controls popup for brightness and supported text size.
  4. Save appearance changes and check readability in the intended lighting.

For narrow cells, the renderer may choose a smaller font so the entire value fits.

On-display grid/Wide size preferences are separate from the ordinary desktop package backup.

A dark palette or low brightness can make a functioning display appear blank.

BACK TO TOP ↑

Threshold warnings and extra conditions

Make important values stand out and bring the relevant screen forward.

Compatible screen definitions support independent low and high thresholds. Threshold comparisons are inclusive. You can select warning colors and enable bring-to-front where the layout supports it.

Current firmware supports an additional condition using another valid parameter for qualifying supported warnings. For example, a pressure warning can require a separate operating condition. Missing, stale, invalid, unavailable, or false secondary data cannot activate a qualified warning.

When several screen overrides are eligible, screen-cycle order determines priority. A higher-priority active warning can take over. After all eligible episodes clear, the previous manually selected screen returns.

  1. Select the signal and enter appropriate limits in the current units.
  2. Enable only the warning sides you need and choose colors.
  3. Add a secondary condition where supported, checking both parameter availability and comparator.
  4. Enable bring-to-front if desired, save, and verify the behavior under safe controlled conditions.

Wide Dashboard does not have the same additional-condition fields as other supported warnings.

Threshold warning overrides do not provide acknowledgement or hysteresis. Choose limits that avoid unwanted rapid switching.

Warnings are display behavior. They do not automatically command engine shutdown or alter ECU protection.

BACK TO TOP ↑

Check-engine notifications

See ECU-reported reasons separately from your own thresholds.

Supported firmware displays ECU check-engine information with an engine icon and a reason panel. A newly reported reason opens the panel; tap to dismiss it and tap the icon to inspect it again. Dismissal does not clear the ECU fault.

Missing or stale diagnostic frames retain last-known reasons and mark them unavailable rather than treating silence as a cleared fault. Unknown codes remain numeric rather than receiving a guessed diagnosis.

After a fresh clear, an intermittent recurrence can light the icon without repeatedly reopening the panel. A reason must remain clear in fresh data for 30 seconds before it rearms its automatic popup. A different new reason can open immediately.

  1. Enable the ECU's required diagnostic broadcast groups.
  2. Keep Check-engine warnings enabled in Gauge Settings if you want these notifications.
  3. When the panel appears, inspect and scroll through all reasons.
  4. Use the ECU's own diagnostic procedure to investigate or clear a fault.

Disabling check-engine notifications does not disable your configured threshold warnings.

Demo Mode does not manufacture check-engine faults.

Do not use a dismissed panel as evidence that a fault has been resolved.

BACK TO TOP ↑

Live and peak values

Review the maximum observed values without creating a data log.

Peak tracking records the highest valid finite value observed for each signal. It is a maximum, not a minimum or an absolute-magnitude extreme.

Tap the central peak target to toggle Live and Peak. Hold it for three seconds to clear the peaks belonging to the current screen. The display provides temporary clear feedback.

Peak state is volatile and is not a persistent trip log. Rebooting or relevant runtime resets can clear it.

  1. Allow live valid data to arrive.
  2. Tap the peak target and review the recorded maxima.
  3. Hold for three seconds to start a fresh peak observation on the current screen.
  4. Return to Live before relying on the display for current operating values.

A saved peak can differ from the present ECU value. Check the Live/Peak indication.

Missing data is not a zero reading.

BACK TO TOP ↑

Demo Mode and simulator

Explore layouts without treating simulated values as vehicle data.

The physical gauge's Demo Mode sweeps each active ECU parameter from its reviewed minimum to maximum in 2.5 seconds and back in 2.5 seconds. Incoming ECU values are ignored for the demo presentation.

Demo Mode is volatile: it stays active after a configurator disconnect and turns off on reboot. The desktop simulator is a separate way to explore the application without a physical gauge.

  1. Use Diagnostics to enable Demo Mode on a connected compatible display.
  2. Inspect the selected layouts, units, colors, scales, and warning presentation.
  3. Disable Demo Mode and confirm live ECU values before returning to normal monitoring.

Disconnecting the app does not stop a running gauge demo.

A smooth moving demo proves presentation behavior, not ECU communication or sensor accuracy.

BACK TO TOP ↑

Virtual Controls overview

Configure supported analog and digital CAN inputs carefully.

Virtual Controls provides configurable analog selectors, presets, and digital toggle or momentary switches on supported ECU/device combinations. MS3 offers four analog channels and eight digital channels, with up to three presets per analog channel.

On the compact display, analog adjustment uses a central dial and selection/preset pills; digital switches use a compact grid. Expanded displays use their larger control interface. A paired rotary controller can navigate and adjust the gauge's controls.

The configuration app defines names, ranges, presets, switch modes, and CAN setup. Normal live operational values are not sent by editing a configuration file or a Bluetooth settings packet.

  1. Confirm that your ECU profile and firmware support the intended control backend.
  2. Leave the master output disabled while preparing labels, ranges, presets, and receiver setup.
  3. Configure the ECU receiving rows and intended behavior using the matching setup instructions.
  4. Verify identifier conflicts, communication-loss behavior, and safe fallback before enabling outputs.
  5. Enable only the required controls and test each one in a controlled stationary setup.

These are CAN messages interpreted by the ECU, not general-purpose physical output pins.

Momentary actions release on touch loss, warning interruption, screen exit, and reboot. ECU reaction to stopped messages must still be verified.

Receive-only display use does not require Virtual Controls to be enabled.

BACK TO TOP ↑

MegaSquirt Virtual Controls setup

MS3 1.6.2 uses Generic CAN Receiving.

The documented output-control target is MS3 firmware 1.6.2. The gauge sends standard-ID CAN state frames; it does not implement remote table polling. The default analog/digital IDs are decimal 1900 and 1901.

The configurator provides numbered TunerStudio instructions and a copy-exactly mapping for CANADC13–16 and CANIN1–8. The gauge passively checks the configured identifiers before allowing normal output.

MS3 1.6.2 can retain its last received Generic CAN input when messages stop. Do not assume disconnecting or powering off the gauge resets the ECU input.

  1. Open Virtual Controls and follow its current TunerStudio setup table.
  2. Match both identifiers, channel assignments, scaling, and byte layout exactly.
  3. If the gauge reports Setup conflict, use the configurator's recovery action and copy both replacement IDs into TunerStudio.
  4. Check all configured outputs and the ECU's behavior when communication stops.
  5. Enable the master only after the receiver and fallback behavior are understood and tested.

Configuration defaults keep output disabled.

Custom identifiers must avoid existing traffic; a conflict inhibits output until the identifier pair is changed.

The controls' eventual function is determined by your ECU configuration.

BACK TO TOP ↑

DTA and Haltech control limits

Output support has narrower requirements than receive support.

DTA controls use extended identifier 0x1005 on compatible devices. The two documented analog words are actual millivolt values across an unsigned 16-bit range, not MS3-style 0–1023 counts. Live DTA bus validation remains pending.

Haltech defaults to receive-only. The implemented Nexus Generic CAN backend requires compatible Nexus hardware, NSP 1.48+ and ECU firmware 1.36+. Elite and Rebel do not have this output backend.

Nexus control configuration supports continuous 0–1023 values or stepped trims with 2–32 positions, plus switches. The default pair is 0x7A0/0x7A1, subject to conflict checks; it is not a globally reserved allocation.

  1. Confirm the exact supported receiver before selecting an output backend.
  2. Use the configurator's setup rows to configure receiver assignments and timeout/fallback behavior.
  3. Keep outputs disabled until live ECU validation and safe failure behavior are established.

Haltech live decoding, receiver assignments, rotary behavior, and communication-loss behavior were not physically qualified by the reviewed implementation record.

Do not describe these unverified output paths as guaranteed plug-and-play vehicle controls.

BACK TO TOP ↑

Rotary 1.28 and Rotary 1.46

Two touchscreen rotary controllers for a compatible paired gauge.

Rotary 1.28 has a 1.28-inch, 240 × 240 round display. Rotary 1.46 has a larger 1.46-inch, 360 × 360 round display. Both combine a rotary encoder, press selection, and capacitive touch. They share the same companion-control role; the larger model does not add standalone ECU control.

Supported rotary controllers pair with a gauge and act on its authoritative state. They support navigation, control focus, and click-turn-click analog adjustment where the connected firmware advertises those functions.

The controller can mirror compatible check-engine information and dismiss a startup splash over an active authorized connection. It is a companion to the gauge rather than a standalone ECU-control transmitter.

  1. Use the controller's installation and pairing instructions for your exact model.
  2. Confirm the intended gauge association before using navigation or controls.
  3. Test rotation, selection, dismissal, and reconnect behavior while stationary.

Controller firmware and gauge firmware must support the same optional functions.

A connection or pairing indication is not proof that the ECU has accepted an output command.

Physical and electrical qualification remains in progress. These controllers require an appropriate CAN interface and a compatible paired gauge. Each includes its housing and a 6 ft harness; controller-specific mounting dimensions and final wiring instructions remain to be confirmed.

No haptic or buzzer function is supported on these controller models. Screen size is not a mounting dimension.

BACK TO TOP ↑

Custom startup image

Prepare an image and set its startup timing.

Startup Splash accepts JPEG, PNG, WebP, BMP, and GIF files up to 10 MB, with a decoded limit of 64 megapixels. Animated files use their first frame. Images can be cropped, zoomed, positioned, and placed on a background color.

The splash can hold for 0–60 seconds and optionally fade in/out over 0.01–10 seconds each. The preview shows the composed display pixels; saved changes take effect on the next boot.

A tap or encoder press dismisses playback. Warnings take priority. A paired controller can also dismiss it when the devices support the feature.

  1. Open Startup Splash, select the correct device, and Read from device.
  2. Choose Image, then crop or adjust placement for the screen shape.
  3. Set background, enable state, hold, and optional fades.
  4. Use Play / Stop Preview, then Save splash settings and wait for confirmation.
  5. Reboot at an appropriate time to inspect the actual startup presentation.

The splash page saves separately from normal configuration. Configuration JSON does not include the image.

To remove the installed image, choose Remove Image and then Save splash settings. Turning the feature off retains the stored image.

If a transfer is interrupted near completion, Read from device to establish what was installed before retrying.

BACK TO TOP ↑

Firmware updates and recovery

Use a device-matched update package and preserve configuration.

Firmware Update accepts a .cgfw package and checks hardware identity, revision, device identity, storage, and security information before transferring firmware. A mismatched package is rejected.

Before a display update, the application attempts a complete local configuration backup. Review any settings-impact information for migrations, resets, removed settings, or items requiring review. Restart is a separate step after verification.

Some older storage layouts require a specific USB upgrade procedure; an application-only wireless update cannot replace every partition layout. Follow the release instructions for your exact version.

  1. Use a stable power supply and a package intended for the exact device.
  2. Update the configurator first when the firmware release requires a newer app.
  3. Connect the intended gauge or controller and select its session in Firmware Update.
  4. Review preflight checks, the backup result, and settings-impact details.
  5. Transfer, wait for verification, then perform the requested restart.
  6. Reconnect, read settings, and verify units, screens, warnings, controls, and live ECU data.

Do not substitute raw development or diagnostic images for customer firmware.

A configuration backup does not necessarily include the startup image or every gauge-local preference.

If an update is rejected, resolve the stated mismatch; do not force another hardware target.

BACK TO TOP ↑

Update the configurator

Keep the Windows app compatible with current gauge firmware.

Installed releases can check for updates at startup. App Updates under Support also provides a manual check and an automatic-check preference.

You can download an offered update, postpone it, or skip a version. Verified downloads can be installed now with an app restart, or explicitly scheduled for application close. Installation waits for active device operations and prompts about unsaved changes.

  1. Open Support, then App Updates, and check for an update.
  2. Download the offered release and wait for verification.
  3. Finish device transfers and preserve unsaved work.
  4. Choose the desired install option, then confirm the installed version after restart.

A manual check still works when automatic startup checks are disabled.

The updater does not save unsaved edits to a gauge for you.

BACK TO TOP ↑

Troubleshooting

Start with identity, protocol, freshness, and the saved configuration.

No data or dashes: check power, CAN wiring, ECU broadcasts, bitrate, active profile, and Demo Mode. A never-received or stale value is intentionally unavailable. The shared runtime uses a 500 ms freshness timeout for normal signal data.

Only one parameter is missing: confirm that its broadcast group is enabled and that the ECU version actually supports the channel. A catalog entry alone does not enable its source.

The screen does not change: ensure at least two distinct screens are enabled. Use a short edge tap; a warning override or open popup can own navigation.

Cannot save: read the device, resolve validation messages, check version compatibility, and confirm the connected hardware. After an interrupted save, reread before retrying.

Bluetooth cannot connect: check Windows permissions and that the intended gauge is advertising. Rescan or try the supported USB path. USB cannot connect: use a data cable and verify the exact device identity.

Unexpected control state: keep outputs disabled, inspect receiver mapping, resolve Setup conflict, and test the ECU's response to communication loss. Do not assume stopped CAN traffic clears retained ECU inputs.

  1. Record the display model, firmware and configurator versions, active ECU profile, and connection method.
  2. Capture the exact error and whether all values or only one signal is affected.
  3. Save a local configuration backup if you can read the device.
  4. Contact support with those details and a clear description of the steps that reproduce the problem.

Do not erase all device storage as a first troubleshooting step.

If the display freezes or loses data, stop relying on it for monitoring until the cause is resolved.

BACK TO TOP ↑

Feature availability and validation

Understand what implementation and hardware checks establish.

Features in this manual reflect current firmware and desktop code, not a guarantee that every shipped device already has the latest release. The configurator's negotiated capability and version checks determine what can be edited.

MegaSquirt development records include physical gauge deployment and live MS3 receive evidence. DTA has software and physical protocol-selection checks but still needs live ECU/bus validation. Haltech is implemented and has software and configuration checks, with live ECU/bus validation still pending.

Hardware acceptance is feature- and model-specific. Screen rendering tests, demo performance tests, USB readback, and successful flashing do not independently establish ECU reception, control assignments, or safe communication-loss behavior.

Ask for confirmation of your exact ECU, display, firmware, and intended control function before relying on prerelease compatibility.

This manual makes no claim of vehicle-specific fitment, regulatory certification, waterproofing, or universal ECU support.

BACK TO TOP ↑